02Piezoelectric & scintillation

Crystals that behave
the way the datasheet
said they would.

Boules, blanks, plates and finished elements from growers we can trace to a single growth run. Orientation, dopant level and light yield go into the quotation as numbers — not into a phone call after delivery.

01Piezoelectric

Single-crystal piezoelectrics

Chosen for stability and low loss, not for raw displacement. If your design needs a large d constant you want PMN-PT; if it needs a frequency that does not drift, you want quartz — and the two are not interchangeable no matter what a trading company tells you.

Values below are typical room-temperature figures for the common cuts. Coupling and temperature behaviour change with cut angle, so the number that matters is the one measured on your lot.

Table 1 · Piezoelectric constants by material and cut

Material Common cuts Piezo constant pC/N Coupling k typ. Curie / limit °C Density g/cm³ Typical use
α-Quartz SiO₂ X, Y, Z, AT, ST, SC d₁₁ 2.31 0.10 573 α→β 2.65 Resonators, delay lines, pressure & force sensors
Lithium niobate LiNbO₃ Y/Z, 128° Y-X, X-cut d₃₃ 6.0 d₁₅ 69 0.17–0.49 1,140–1,210 4.64 SAW filters, EO modulators, ultrasonic transducers
Lithium tantalate LiTaO₃ Y/Z, X-cut, 36° Y-X d₃₃ 5.7 0.19–0.40 600–620 7.45 Pyroelectric detectors, SAW, IR optics
Langasite La₃Ga₅SiO₁₄ X, Y, Z d₁₁ 6.7 0.16 none to 1,470 melt 5.75 High-temperature sensors, downhole, aerospace
PMN-PT relaxor 〈001〉 poled d₃₃ 1,500–2,500 0.85–0.92 130–170 Tm 8.1 Medical ultrasound, actuators, sonar
AlN bulk & thin film c-axis d₃₃ 5.0–5.5 0.25 kt >1,000 3.26 HBAR, MEMS, high-temperature SAW

Scroll the table sideways for all columns →

Note on k. The electromechanical coupling coefficient is a property of the cut, not of the material alone — the same LiNbO₃ boule gives a very different k on 128° Y-X than on Y-Z. We quote against your resonator design and ask the grower for measured impedance data, not a catalogue figure.

02Scintillation

Scintillator crystals

Light yield, decay time, density and hygroscopicity pull against each other. The right choice depends on whether you are counting photons slowly and precisely, or timing them in nanoseconds — so we start from your detector, not from a price list.

Table 2 · Scintillation properties, typical values

Material Light yield ph/MeV Peak λ nm Decay ns Density g/cm³ Hygroscopic Where it wins
NaI(Tl) 38,000–45,000 415 230 3.67 Yes General gamma spectroscopy; best resolution per dollar
CsI(Tl) 52,000–56,000 550 680–1,000 4.51 Slight Rugged detectors, good match to photodiodes
CsI(Na) 39,000–43,000 420 460–630 4.51 Yes Higher Z, faster than CsI(Tl), good blue match
BGO 8,000–9,000 480 300 7.13 No High stopping power; PET, calorimetry, no packaging drama
LYSO(Ce) 25,000–32,000 420 40 7.1 No TOF-PET and fast timing
GSO(Ce) 8,000–10,000 440 30–60 6.71 No PET, well logging, high count rates
GAGG(Ce) 46,000–58,000 520 90–100 6.63 No Bright and non-hygroscopic — the usual NaI(Tl) replacement
LaBr₃(Ce) 61,000–70,000 380 16–35 5.08 Yes Best energy resolution and fast decay together
CeBr₃ 57,000–66,000 380–390 18–20 5.10 Yes LaBr₃ performance without intrinsic activation
SrI₂(Eu) 80,000–115,000 435 1,200 4.55 Yes Highest light yield available; isotope ID
CaF₂(Eu) 19,000–30,000 435 950 3.19 No Large-area panels, low intrinsic background

Scroll the table sideways for all columns →

Note on light yield. Published figures assume a specific size, dopant concentration and readout. A 1-inch cube and a 4-inch cylinder of the same CsI(Tl) do not produce the same number. Every quotation we send names the size the figure refers to, and we ask for the grower's own pulse-height spectrum on the lot being shipped.

03Written into the order

Three things we refuse to leave verbal

A crystal quotation that says "high quality, no bubble" is not a specification. These are the three headings we insist on filling with numbers before a PO is issued — and the same three we check against at pre-shipment.

Tolerance01

Orientation

Measured, not stamped. A Laue or XRD rocking curve per boule, referenced to the flat or notch on the actual part.

Cut tolerance
±10′ (0.17°)
Off-axis
per your design
Flat / notch
to your datum
Report
XRD per lot
Chemistry02

Purity & dopant

The difference between two "NaI(Tl)" quotes is usually the thallium concentration — and it moves the light yield by tens of percent.

Trace metals
ICP-MS
Dopant level
±5% of target
OH content
quartz, on request
Colour centres
visual + spectra
Finish03

Surface & coating

Polish quality decides how much light ever reaches the photocathode. We hold the polish and the coating curve in the same document.

Polished Ra
≤0.5 nm
Parallelism
≤10″
TTV
≤5 µm
AR / HR
curve supplied

04Qualification

How we qualify a grower

Six checks, done before the first paid order. On a new supplier we do them at the factory; on a repeat supplier we do them per lot and send you the file.

01

Boule traceability

The lot number must resolve to a growth run — furnace, date, seed — not to a warehouse bin. We ask to see the run log and match it to the parts we are buying.

02

Orientation by measurement

Laue back-reflection or XRD on the finished part, with the flat or notch in frame. A stamp on the box is not evidence; we have seen boxes stamped correctly and parts cut 2° off.

03

Phase and Curie point

For ferroelectrics, a dielectric peak or DSC trace near the stated Curie temperature. For quartz, a check for twinning under cross-polarised light — the defect that quietly halves Q.

04

Inclusion and bubble scan

Cross-polarised inspection against a ruled background, photographed. We count and locate, per part, against the acceptance number written in the PO — not "few, acceptable".

05

Transmission on the lot

A spectrophotometer curve from 200 to 2,500 nm on the material actually shipping. Catalogue curves are for catalogue material; absorption bands show up in the lot, not the brochure.

06

Packaging for hygroscopic stock

NaI(Tl), LaBr₃ and SrI₂(Eu) degrade in ordinary air. We verify vacuum sealing with desiccant, and we open and re-seal at pre-shipment inspection so you receive a seal that was closed after we looked.

05Where it goes wrong

Three failures we see most often

Trap 01

"Same grade" re-labelling

A dummy-grade boule is cut, polished and sold as detector grade because the invoice says so. The tell is usually the transmission curve that arrives as a photocopy of a photocopy, with no lot number on it.

Trap 02

Orientation as a stamp

Cutting tolerance is the first thing sacrificed when a factory is behind. Two degrees of error is invisible on a drawing and fatal on a resonator — and no one discovers it until the parts are already at your assembler.

Trap 03

The mount, not the polish

Most yield loss happens after the crystal is perfect: bonding, potting, thermal cycling. We ask for the assembly drawing early, because the finish and the flatness have to be chosen for the mount, not for the inspection report.

Send a drawing, or a spec sheet you were given.

We will come back with the grower, the grade we would accept, the numbers we would write into the PO — and the price with the factory invoice attached.